Approved Addressable Fire Alarm Systems
Addressable fire alarm systems, also known sometimes as Intelligent Fire alarm systems are designed to be used in places where the network of detectors and the fire system is complex and complicated.
Addressable systems work on the concept of unique addresses for each device connected in the network. Each call point or detector in the network is connected in loops which can be easily addressed using the control panel of the addressable fire alarm system.
These systems are different from Conventional system as they point out the exact device that is being alarmed and not just the zone unlike the conventional systems.
This can save time and also help in rapid action in situations of fire.
ADDRESSABLE MULTISENSOR WITH ISOLATOR A50SHCOI
Addressable multisensor with isolator detector
The A50 family of detectors are based on a new refined aesthetic that integrates the latest electronic technology with new, more efficient detection algorithms and a three-dimensional design that makes it more robust against environmental dirt.
The A50 family allows multiple combinations between smoke and heat detection, CO sensor and short-circuit isolator with UL certification.
The A50SHCOI model is a multi-sensor detector that has a short-circuit isolator and three different types of sensors: An smoke sensor, a heat sensor and a Carbon Monoxide (CO) sensor.
The use of the CO sensor is very valuable for the early detection of some types of fire, since the production of this gas is very common, especially in the initial phases of a fire. Its integration with the smoke sensor results in a compact detector that is very robust against false alarms.
To complete its features, a heat sensor with thermovelocimetric response is incorporated, reaching alarm status with a static temperature of 60ºC in the case of slow fire developments.
UL CERTIFICATE.
PUCPR / PUCDR ACTIVATION AND LOCK MANUAL CALL POINT
Lock and trigger manual call point of extinguishing systems by gas agents. Immediate visual recognition of manual activation by the permanent activation of the LED, and the trigger of the yellow tab on the lower side of the activation face. Manual call point, easily resettable by a yellow switch in the front face.PUC-PR model: manual call point for STOP EXTINGUISHING (blue color) to use with conventional CLVR02EXT control panels
Data Center fire detection and extinguishing system
Automatic fire extinguishing system for kitchens composed of an automatic detection system based on 9l, 12l and 25l capacity extinguishers, which provide a stainless steel pipes system on which diffusers are connected to the possible origins of the fire (stove, grill, fryer, etc.) and at least one above the filters and another in the smoke outlet 30 cm into the pipe